Microhidraulica

RCD DIFFERENTIAL PRESSURE FLOWMETERS

Flow Pressure Level Temperature measurement monitoring control

? ? ? ? ?

0.2-0.88 to 100-600 GPM Liquids 0.3-3 to 250-1650 SCFM Gases 1/2” to 3” Line Sizes Bronze or 316-Ti Stainless Steel Mechanical Indicator, Digital Indicator, Transmitters and Switches Available ? Custom Calibrations for Density and Viscosity

S5

USA
KOBOLD Instruments Inc.1801 Parkway View Drive USA- Pittsburgh, PA 15205 ? +1 412-7 88 – 28 30 Fax +1 412-7 88 – 48 90 E-mail: [email protected]

CANADA
KOBOLD Instruments Canada Inc. 9A Aviation Pointe-Claire, QC H9R 4Z2 ? +1 514-428-8090 Fax +1 514-428-8899 E-mail: [email protected]

Visit KOBOLD Online at www.kobold.com

Model:

RCD

Rev.4 7/09

199

RCD – Differential Pressure Flowmeters

Features? 0.2-0.88 to 100-600 GPM Liquids ? 0.3-3 to 250-1650 SCFM Gases ? 1/2” to 3” Line Sizes ? Bronze or 316-Ti Stainless Steel ? Mechanical Indicator, Digital Indicator, Transmitters and Switches Available ? Custom Calibrations for Density and Viscosity

The RCD series differential pressure flowmeter measures flows of liquids and compressed gases using the orifice principle. The orifice, located inthe flow body, generates a differential pressure which varies with flowrate. The differential pressure is applied to a measuring bellows. The measuring bellows is linked either to a mechanical indicator, or to a hall effect sensor, which is input to a compact or full featured electronic display and controller.

RCD series Differential Pressure Flowmeter

Specifications
The unique KOBOLD designfeatures a single measuring bellows making its accuracy unaffected by system pressure fluctuations. The meter movement is a single fulcrum lever design which is simple, yet very reliable, with a minimum of wear parts. The RCD is available with bronze or stainless steel bodies ranging in size from 1/2” NPT to 3” NPT. The various electronic display and control units offer a variety of options suchas digital or bargraph displays, adjustable switches and flow transmitters. Flow Ranges Liquids: Gases: Indicator Housing: 0.2-0.88 GPM through 100 to 600 GPM 0.3-3 SCFM through 250 to 1650 SCFM ±3% of full scale ±1% of full scale Epoxy coated aluminum, polycarbonate, NEMA 4X

Wetted Materials Bronze Versions: Bronze, 316-Ti stainless steel, buna-n SS Versions: 316-Ti stainless steel, FKMAccuracy: Repeatability:

Maximum Temperature: Mechanical Display: 212°F Electronic Display 176°F Maximum Pressure: 580 PSIG Maximum Pressure Drop: 5 PSI

200

Minimum Operating Pressure: 10 PSIG

Subject to change without prior notice.

RCD – Differential Pressure Flowmeters

RCD-Z Specifications
Flow Units Liquid: Gases: Optional: Enclosure: GPM SCFM LPM, M3/Hr, special scales onrequest Epoxy coated aluminum & polycarbonate, NEMA 4X

RCD-Z Mechanical Indicator

RCD-C Specifications
Input Power: Display: Switch: 24 VDC ±20%, 80 mA 3 digit LED PNP or NPN open collector, 300 mA Max. short circuit protected 4-20 mA 3 wire 304 SS, NEMA 4X Micro-DC male, 5-pin

Flow Transmitter: Housing: Electrical Connection: RCD-C Compact Electronics

RCD-K Digital Display/ControllerRCD-K Specifications
Input Power: Display: Relays: 115 VAC, 24 VDC, 24 VAC, 48 VAC or 230 VAC 3-1/2 Digit LED and Bargraph, 270? 2 SPDT programmable setpoint, 5 amps @ 230 VAC 4-20 mA, 4-wire Epoxy coated aluminum & polycarbonate, NEMA 4X

S5

Flow Transmitter: Enclosure: RCD-K Digital & Bargraph Display/Controller

*For all versions calibrations for compressed gases, liquid viscosity anddensity available.

Subject to change without prior notice.

201

RCD – Differential Pressure Flowmeters

Ordering Codes For Liquid Flowmeters
(Example: RCD-1106GN5C34P)

Range GPM

Orifice Dia. (mm) 2.80 3.15 3.50 4.00 4.50 5.00 5.60 6.30 7.10 8.00 9.00 10.0 11.2 12.5 14.0 16.0 17.5 19.2 26.0 28.0 31.0 33.5 40.0 43.5 51.0 60.0 67.0

Body Material Bronze RCD-1195G RCD-1100G…