Manual planta electrica generador gensets

Prime Model:P15PX Emergency Model:P16.5EX

DIESEL GENERATOR SET 208V-480V
ISO 9001:2000
SWT DIESEL GENERATOR SET
THE INTERNATIONAL CERTIFICATIONNETWORK

3P4W

Standard Features and Characteristics
QUALITY STANDARDS The SUPERWATT generator set compliance with all main standards, such as ISO8528 GB/T2820-97), GB755 BS5000, VDE0530, ISO3046, IEC34-1, CSA22-2, AS1359, ISO14001. Dieselengine and alternator OEM authorization certificate and their quality assurance. Other standards and certifications can be considered on request. ASSEMBLY The engine and alternator are close coupled by means of an SAE flange . A full torsional analysis has been carried out to guarantee no harmful vibration will occur Anti-vibration pads are affixed between engine alternator feet and the baseframe. Thusensuring complete vibration isolation of the rotating assemblies and enabling the machine to be placed on an uneven surface without any detrimental effects. For durability and corrosion resistance, all iron and steel surfaces of canopy fabrications have been treated for coating by grit blast cleaning. Then covered by a polyester powder paint which provides an excellent corrosion resistantsurface. CONTROL SYSTEM AND PROTECTION Controllers are available for all applications. The controller system is used to start and stop the engine , indicate electric date and protect the generator set.See controller features inside. The revolving parts are covered by safety net , and the place which easy to scald and got an electric shock all to have the obvious warning slogan WARRANTY

Rating RangeEmergency: Prime: kW k VA kW k VA 1800RPM 60Hz 13.2 16.5 12 15

GENERATOR SET RATINGS
Alternator Model Frequency and Speed Prime Power Data Class-TEMP Rise( ) Voltage series star Voltage parallel star Voltage series delta Rating capacity(kVA) Rating power(kW) Power efficiency(%) Input power(kW) 416 208 240 16.0 12.8 80.3 15.8 Cont.H -125K/40 440 220 254 16.9 13.5 80.4 16.8 460 230 266 16.9 13.581.0 16.7 480 240 277 16.9 13.5 81.5 16.6 N/A 416 208 240 Cont.H -125K/40 440 220 254 460 230 266 480 240 277 BCI164C(STAMFORD) 60Hz 1800rpm N/A (LEROY SOMER) 1800rpm

SUPERWATT Company provides one-source responsibility for the generator set and accessories.
60Hz

Each SUPERWATT generating set has been got through 2 hours load test for running 0%,25%,50%,75%,100% and 110% load, allprotective devices and control function are stimulated and checked before dispatch. All equipment is guaranteed for the period of 1000 hours or 12 mouths from the date of commissioning or 18 months from shipping, whichever occurs first. Convenience for operation and maintenance, backed by PERKINS ,NEWAGE(CUMMINS) and LEROY SOMER global service network.

Standby Power Data Class-TEMP Rise( ) Voltageseries star Voltage parallel star Voltage series delta Rating capacity(kVA) Rating power(kW) Power efficiency(%) Input power(kW) N/A N/A Standby.H -125K/40 416 208 240 440 220 254 460 230 266 480 240 277 Standby.H -150K/40 416 208 240 440 220 254 460 230 266 480 240 277

RATINGS: All three-phase units are rated at 0.8 power factor. Standby ratings : Standby ratings apply to installations served by areliable utility source. The standby rating is for this rating. Ratings are in according with ISO-3046/1,BS 5514 ,AS 2789 , and DIN 6271. Prime Power Ratings: Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings arein accordance with IS0-8528/1, overload capacity in accordance with ISO-3046/1,BS 5514, AS 2789, and DIN 6271. For limited running time and base load ratings, consult the factory. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. GENERAL GUIDELINES FOR DERATION: Altitude: Derate 2.0% per…